Following are guidelines for care and maintenance of INSpect GS bulkheads:
-
All mounting and sealing surfaces require a 32 finish.
-
Lubricate mating surfaces with 3M Silicone Spray or equivalent, DO NOT GREASE! Connectors must be lubricated on a regular basis.
-
Lubricate o-rings with Dow Corning #111 Valve Lubricant or equivalent.
-
Use Dust Caps and keep connectors clean to prevent damage in storage and service.
-
Keep o-ring grooves clean and avoid cuts, nicks and tears on rubber surfaces.
-
Elastomers can be seriously degraded if exposed to direct sunlight or high ozone levels for extended periods of time.
-
Clean plugs and receptacles with soap and fresh water.
-
Rinse out with alcohol, allowing connector to air dry.
-
Replace o-rings when re-using connectors