Pre-Dive PreparationsSelect a safe and preferably level area to set up the User Control Console. See the On-site Operations section of the Project Management Guide for more information about site selection and set up. The pre-dive preparations consist of five parts:
Conduct a Visual InspectionAssuming this is your first time using the VideoRay, everything should be in proper working order and ready to go, but it is good practice to perform a pre-dive inspection before every dive, even your first. If any problems are noticed, they should be addressed before continuing.
Make the ConnectionsIt is best to start making connections at the ROV and working your way to connecting the system to the power source. Connecting or disconnecting cables while the system is powered on is not recommended. Make sure the User Control Console power switch is set to the Off position and make sure the ROV power switch is set to the off position by pressing it. Top View Side View Some of the cables have been connected at the factory. See the appropriate sections of the Equipment Guide for detailed information about each of the connections. You will typically need to connect only the ROV, tether, strain relief hand controller, and power cord.
Power On TestsIf the system does not pass any of the following tests, it should not be used until the problem is identified and corrected. The VideoRay MSS includes two circuit safety components.
Testing the Circuit Safety ComponentsConnect the power cord to a suitable power source. The GFCI can be found inline in the power cord.
When using a power source that includes a GFCI, the VideoRay supplied GFCI is not needed and can be removed from the power cord. Power On and LIM TestsSet the Power switch to the On position. The green Power On indicator light should turn on. If the green Power On indicator light is not on, make sure the system is connected to a working power source and the GFCI switch is turned on. Twist the ROV Power switch to the On position. The green 400 V Power On indicator light should turn on. If the green 400 V Power On indicator light is not on, make sure the system is connected to a working power source and the GFCI and main power switches are turned on. Test the LIM. The LIM can be found on the right side of the User Control Console. The GFCI switch and the main and 400 V Power switches must both be set to On in order to perform this test.
Starting the VideoRay Control SoftwareMake sure the system is connected to a working power source and the GFCI / Circuit Breaker and Power switches are turned on.
See the Software Guide for more information about the VideoRay control software. Testing the System's FunctionsThe next step is to ensure that the essential features of the ROV are functioning properly. Use the hand controller to perform the following tests. The manipulator functions listed below do not necessarily represent the full capabilities of the system. See the Hand Controller section of the Equipment Guide for the complete list of functions and more information about using the hand controller.
Additional features and controls may be available depending on the system configuration. These tests represent the minimum set for all configurations. Test the thrustersFor the next two steps, do not operate horizontal thrusters out of water for more than 30 seconds to avoid overheating or premature wear of the cartridge seals.
Test the lightsFor the next two steps, do not leave the lights on bright for more than 30 seconds while the ROV is out of water to avoid overheating.
Test the camera functions
If a manipulator or other accessories are attached, these items should be checked at this time. |
||||
Good AdviceThe time to catch small problems before they become big problems is during the pre-dive inspection. [ Help us improve this document ] [ Print this page ] |