Leak Detector Use
- Remove the float block.
- Remove the vertical propeller.
- Remove the vertical cartridge seal.
- Install the cylindrical body on the vertical shaft with the O-ring down. Make sure the O-ring is seated.
- Install the retaining plate with the larger hole over the cylindrical body and the smaller hole over the float block stud.
- Install the retaining screw in the float block stud to hold the device in place.
- Using a hand pump connected to the valve, pressurize the ROV to no more than 35 - 70 kPa (5 - 10 psi).
- Place the ROV in water.
- Observe the ROV for any signs of escaping bubbles.
- If bubble are observed, perform any necessary remedial action.
- Replace the vertical cartridge seal.
- Replace the vertical propeller.
- Replace the float block.
|