VideoRay Radiation Sensor Operating Tips
Hardware Set Up
- Remove entire skid from the VideoRay ROV by removing the 4 Phillips head screws that go through the dome retainers and into the skid from the front and back.
- Fit the Radiation Detector to the dome retainers with the long probe end protruding to the front, and replace the 4 retaining screws removed in step 1.
- Plug the cable from the Radiation Detector into the accessory port.
- You may have to add or subtract weights to suit your particular setup and water conditions.
The ROV accessory port should be sealed with either a dummy plug or the manipulator or cutter.
Operation
- Run AW-RADW.exe by double clicking on it.
- It should start up and report "COM x Present" where x is the COM port to which the serial cable from the VideoRay control box is connected.
- Click on "Rad Collection" then "Express Start Collection of Rad Data."
- Follow the command prompts for file name, etc.
- After setting up the file names and logging options a graph window should open in addition the logging window labeled Aw-Radw.
- Both windows should now be displaying a new data point every 10 seconds. To adjust the frequency of display, stop the collection (Rad Collection>Stop the Rad Collection). Change the Time Base Unit (TBU) (Rad Options>Time Base Unit>Time Base Unit). Set the time base unit to a low value to increase the frequency of the graph points, or a high value to decrease the frequency of the graph points. Note: The Time Base Unit does not affect the click sound frequency.
This equipment is optional and may not be included in all VideoRay Pro 4 configurations.