Camera Mount Base Assembly Replacement Procedures

Time required for this step: Approximately 4 Minutes

Tools required for this step:

Parts involved in this step:

CAM-HSG-R Camera Mount Base Assembly

QuantityPart NumberPart Description
1CAM-HSG-RCamera Part Mount Base Pivot Block (Pro 4)
296640A056Screw #4-40 x 3/8" Flat Head Phillips SS Black

Steps

  1. Orient the camera mount cover (with camera and focus servo motor installed) so that the camera is on the left when viewed from the rear.

  2. Make sure the camera and camera focus servo motor are fully seated in the camera mount cover and place the camera mount base on the camera mount cover.

  3. Orient the camera mount base so that the tilt gear shaft is on the left when viewed from the rear and the interface board is to the rear.

  4. Place the camera mount base in position on the camera mount cover. Make sure the focus servo motor wires are routed away from any of the mount bosses or camera components so the wires do not get pinched.

  5. Replace the two 6-32 X 3/8 inch Phillips flat head screws that hold the camera mount base to the camera mount cover and tighten them.

If the video above doesn't play in your browser, click this play icon to try an alternate method: , or click this manual reference icon to view an exploded view